19" Touchscreen OR Control Panel — HVAC, Lighting, Gas & Safety Monitoring

The ORC-419 is the most widely deployed OR control panel in the CureVision ORC series — a 19-inch capacitive touchscreen workstation that centralizes control of every environmental and safety system in the operating room from a single wall-mounted interface.

The ORC-419's 19-inch format fits standard OR wall configurations while providing clear, single-operator visibility of all environmental parameters — making it the practical choice for most surgical suite installations, from standard ORs to specialty procedure rooms.

✓ Capacitive Touch ✓ IP65 Front Protection ✓ Built-in Installation

Key Specifications:

Environmental Monitoring & Control: Continuously monitors and controls temperature, humidity, differential pressure, and HEPA filter status — with real-time warnings for out-of-range conditions and automated alerts before sterility is compromised.

HVAC & Air Handling Control: Integrated BMS and HVAC control manages airflow, half-damper shut-off, and economic standby mode — reducing energy consumption during low-demand periods without manual intervention.

Lighting Control — Surgical & Armature Groups: Control surgical lights and four independent armature groups with individual dimmer functions — adjusting OR lighting precisely to each procedure's requirements without leaving the sterile field.

Medical Gas Alarm Integration: Monitors medical gas pressure levels across all OR gas lines — triggering audible and visual alarms when pressure deviates from safe operating limits.

Isolation Power System Monitoring: Continuously monitors the OR isolation transformer — detecting leakage, temperature, and current limit breaches with audible alarms, ensuring electrical safety for patients and staff.

Anesthetic Gas Purging Control: Precise control over anesthetic gas purging — ensuring safe removal of waste anesthetic gases from the OR environment during and after procedures.

Hands-Free Video Intercom: Built-in hands-free video intercom enables communication between the OR and adjacent areas — scrub room, control room, or preparation area — without breaking sterile protocols.

Digital Negatoscope Control: Control the digital negatoscope directly from the ORC interface — enabling radiology image display management without a separate control unit or leaving the sterile field.

Operation Table Control (Optional): Optional integration with the OR surgical table — allowing position adjustments to be managed from the central touchscreen without a dedicated table control pendant.

Audio & Music System Control: Complete control over the OR audio and music system — allowing the surgical team to adjust volume and source directly from the touchscreen without manual intervention.

Digital Clock, Procedure Timer & Stopwatch: Real-time digital clock, procedure stopwatch, and timer — displayed on the ORC screen for precise timekeeping during critical phases of the procedure.

Trend Graphs & Parameter Archiving: Historical trend graphs for temperature, humidity, pressure, and HEPA differential pressure — archived automatically for compliance documentation, facility audits, and regulatory reporting.

Multi-Level User Access Control: Password-protected access with configurable user levels — ensuring only authorized personnel can modify critical OR environment settings.

Is the ORC-419 Right for Your OR?

• You need a proven, widely deployed OR control panel format that fits standard OR wall configurations without requiring the larger footprint of the ORC-421
• Your OR environment control is managed by a single operator — the 19-inch display provides clear visibility for one-person operation without excess screen space
• You are standardizing OR control panels across multiple rooms and want the most practical, cost-efficient ORC format
• You want the full CureVision ORC feature set in the most commonly installed configuration

Consider the ORC-421 instead if your OR requires maximum screen size for multi-operator visibility or large-format display preference.
Consider the ORC-417 instead if wall space is limited and the most compact ORC format is required.

Want to see the ORC-419 configured for your OR?

Our team will walk you through installation options, BMS integration, and compatibility with your existing OR infrastructure.

🔗 Request a Consultation

 

Touch Screen Options
Touch Screen Options
Setting and Controlling Parameters
Setting and Controlling Parameters
Handsfree Video Call
Handsfree Video Call
Control and Report Monitors and Systems
Control and Report Monitors and Systems

Sectors

Technical Specifications

System
CPU :
Intel® Celeron® Processor J1900
Cache :
2nd Level depends on CPU
Memory :
2 x DDR3 SoDIMM maks. 4GB / 8GB
Video RAM :
Maks 128 MB shared memory
Control :
Intel® Soc
Watchdog Timer :
255 Level Reset
I/O
Serial Port :
3 x RS-232 Ports
Parallel Port :
SPP/EPP/ECP
USB Port :
4 x USB 2.0
KB / MS :
1 x PS2 K/B and Mouse
LAN :
2 x LAN Realtek Gigabit Ethernet
Wireless LAN :
802.11 b / g (Optional)
Audio :
Line in & out (AC’97 codec audio)
Expansion Slot :
PCIe/MiniPCIe
Data Storage
HDD / Type :
Vibration Resistant 2.5” (500 GB HDD)
SSD :
64 GB / 128GB / 256 GB
Feed
Input :
220VAC or 24VDC
LCD Screen
Type and Size :
19" / 4:3
Max. Resolution :
1280x1024, XGA
Pixel Pitch :
0.297mm x 0.297mm
Max Color :
16.7 M
Brightness (cd/m2) :
350
Contrast Ratio :
1000/1
Viewing Angle :
160°(H),160°(V)
Back Light MTBF :
50,000 hours
Touch Screen :
19" Capacitive Touch
Mechanical & Environmental Features
Operating Temperature :
0 ~ 60°C
Storage Humidity :
5 ~ 95% (non-condensing)
Case :
Heavy Duty Metal Case
Front Frame :
Special Inset Glass
Weight :
Variable according to screen size (1-5 kg)
Dimensions :
Variable according to screen size
Mounting :
Built-in
Order Code
CPU :
J1900 / i5 / i7
PSU :
AC220
RAM :
R4 / R8
HDD :
500GB HDD(Ops) / SSD64 / SSD128 / SSD256
Wifi :
Optional